Home> Products> LV 3PH Asynchronous Motor> Cast Iron LV 3PH Asynchronous Motor> BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor
BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor
BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor
BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor

BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor

Get Latest Price
Payment Type:L/C,T/T
Incoterm:FOB,CIF
Transportation:Ocean
Port:shanghai
Product Attributes

BrandBeide

Application:chemical and petrochemical industries, etc.

Rated Power:0.55 ~ 90 kW

Frame Size80 ~ 280

Voltage And Frequency:Supports multiple voltages and frequencies

Cooling Method:IC411

Insulation System:Class F

Altitude:no more than 1000 meters

Protection Class:IP65

Packaging & Delivery
Selling Units : Piece/Pieces
Download :

The file is encrypted. Please fill in the following information to continue accessing it

Product Description

7.5KW 1TL0001 Cast Iron Asynchronous Motor

At rated output with converter fed operation, the motors will be used in temperature class 155 (F). To prevent damage
as a result of bearing currents, insulated bearings are recommended to be assembled for frame size 250 and above. Please inquire Siemens about the detailed information of insulated bearing.
By usage with admissible torque and below, the motor can be operated with self cooling; by usage over the admissible torque line, the motor with forced ventilation is needed.
7.5KW 1TL0001 Three-Phase Asynchronous Motor,At operating speeds above rated speed the noise and vibration levels increase and the bearing life time reduce. Attention should be paid to the re-greasing intervals and the grease service life.


1TL0001 Cast Iron series Low-voltage Three-phase Asynchronous Motor

0004 7x7 Jpg

Cast iron housing motor

Rated output:0.55 ~ 315 kW Frame size:80 ~ 355
Voltage and Frequency:support multiple voltage and
frequency
Cooling method:IC411
Oiling device:FS180~355 motor as standard Degree of protection:IP55
Degree of insulation:F
Coolant temperature:-15 ~ 40 ºC
Site altitude above see level:not exceed 1000 m
1TL0 series of motors owns the features of high efficiency, novel structure, beautiful appearance, low noise, small vibration, high degree of insulation, etc, also can be used in the fields of fans, pump, compressors and textile machine. The content in this catalogue only be suitable for continuous duty operation(S1), IC416 or IC418 cooling method or under 60Hz.

Company Profile
1TL0001 Cast Iron Three-phase Asynchronous Motor

Siemens Standard Motors Ltd. (SSML)

Siemens Standard Motors Ltd. (SSML) is a Siemens-owned company in China. SSML is located in Yizheng City, Jiangsu Province. The company focuses on developing and producing small and medium low-voltage motors. Currently, SSML mainly produce Siemens brand low voltage AC Motors according to IEC standards, and Beide brand Low Voltage Motors designed according to China local standards.

As one of Siemens main low-voltage motor production facilities worldwide, SSML uses the knowledge and experience of more than 100 years in motor design and manufacturing, owns the advanced manufacture equipment and process, adopts the SIEMENS modern management model , and implements comprehensive quality control according to ISO9001 2015. SSML will continuously serve customers with high quality products and good service.


1TL0001 Cast Iron Three-phase Asynchronous Motor


Construction and mounting type

1TL0001 Cast Iron Three-phase Asynchronous Motor


1) At outdoor application, the using of protective cover (Option code H00) is recommended
2) At out door application the protection of shaft again jet-water is recommended
3) Full circle flange as standard configuration in this type mounting.

Bearing system

1TL0001 series motors are supplied with the ball bearing as standard. These bearings are either of the sealed or regreasable type.
For FS80 ~ 160, the floating bearings are assembled; for FS180 ~ 355, floating bearing at DE, and fixed bearing at NDE assembled.
The standard bearing can endure a maximum cantilever force, the increased cantilever bearing design (Option code: L22) should be considered.


Bearing Assignment

Frame size

 

 


Pole

Standard design

Increased cantilever-bearing (Option code:L22)


DE bearing

 NDE bearing

(Horizontal mounting)

 NDE bearing

(Vertical mounting)


DE bearing

 NDE bearing

(Horizontal mounting)

 NDE bearing

(Vertical mounting)

80

2, 4, 6

6204 2RZ C3

6204 2RZ C3

6204 2RZ C3

90

2, 4, 6

6205 2RZ C3

6205 2RZ C3

6205 2RZ C3

100

2, 4, 6

6206 2RZ C3

6206 2RZ C3

6206 2RZ C3

6306 2RZ C3

6206 2RZ C3

6206 2RZ C3

112

2, 4, 6

6206 2RZ C3

6206 2RZ C3

6206 2RZ C3

6306 2RZ C3

6206 2RZ C3

6206 2RZ C3

132

2, 4, 6, 8

6208 2RZ C3

6208 2RZ C3

6208 2RZ C3

6308 2RZ C3

6208 2RZ C3

6208 2RZ C3

160

2

6309 2RZ C3

6209 2RZ C3

6209 2RZ C3

4, 6, 8

180

2

6310 C3

6210 C3

6210 C3

NU310

6210 C3

6210 C3

4, 6, 8

200

2

6312 C3

6212 C3

6212 C3

NU312

6212 C3

6212 C3

4, 6, 8

225

2

6313 C3

6213 C3

6213 C3

NU313

6213 C3

6213 C3

4, 6, 8

250

2

6314 C3

6215 C3

7215

NU314

6213 C3

O.R.

4, 6, 8

280

2, 4, 6, 8

6317 C3

6217 C3

7217

NU317

6217 C3

O.R.

315

2

6319 C3

6317 C3

7317

NU319

6317 C3

O.R.

4, 6, 8

6319 C3

6319 C3

7319

6319 C3

355

2

6319 C3

6319 C3

7319

NU319

6319 C3

O.R.

4, 6, 8

6322 C3

6322 C3

7322

NU322

6322 C3

O.R.

Note: DE Driven end
NDE Non driven end
-Not possible
O.R. Possible on request


Grease life and re-greasing interval

For permanent lubrication, the bearing grease lifetime is matched to the bearing lifetime. This can, however, only be achieved if the motor is operated in accordance with the catalog specifications.

For motors which can be regreased at defined regreasing intervals, the bearing lifetime can be extended and/or unfavorable factors such as temperature, mounting conditions, speed, bearing size and mechanical load can be compensated.


Grease life (Horizontal installation)

Frame size

Poles

Grease lifetime up to CT 40 ºC 1)

Grease for permanent lubrication bearing

80 ~ 160

2468

20000 或(or 40000 2

Grease for regreasable bearing

180 ~ 250

2

4000 h

180 ~ 250

468

8000 h

280 ~ 315

2

3000 h

280 ~ 315

468

5000 h

355

2

2000 h

355

468

4000 h



























Note:
1) If the coolant temperature is increased by 10 K, the grease lifetime and regreasing interval are halved.
2) 40000 h apply to horizontally installed motors with coupling output without additional axial loads.


■When motor runs beyond the rated speed, the increase of motor vibration will result in the extra radial and axial force on bearing. This will reduce the life of bearing;
■When the motor vibration increase due to the environment
or other equipment, the bearing also will endure more radial and axial force. This also will reduce the life of bearing;
■If the coolant temperature is increased by 10 ºC, the grease lifetime and regreasing interval is halved.

Connection boxes technical data

Frame size

Contact screw thread

Outer cable diameter (sealing range)

Cable entry size

80 ~ 100

M4

1014

M24 x 1.5

112 ~ 132

M5

1318

M27 x 2 + M27 x 2

160 ~ 180

M5

1825

M36 x 2 + M36 x 2

200 ~ 225

M8

2232

M48 x 2 + M48 x 2

250

M10

 

3744

 

M64 x 2 + M64 x 2

280

M10

315

M12

355

M16

3847

M72 x 2 + M72 x 2

Vibration
1TL0001 rotors are dynamically balanced to severity grade A using a half key.
Table below contains the effective vibration values for unloaded motors.

Vibration Grade

Frame size (mm)

56 ≤ FS ≤ 132

H>132

Mounting

Vibration displacement/um

Vibration velocity/(mm/s)

Vibration displacement/um

Vibration velocity/(mm/s)

 

A

Free suspension

45

2.8

45

2.8

Rigid mounting

-

-

37

2.3

2.81)

 

B

Free suspension

18

1.1

29

1.8

Rigid mounting

-

-

24

1.5

1.81)

Note:
1) The level are vibration velocity limit when the twice line frequency vibration level is dominant defined by GB/T 10068-2020, for 2p motors that frame size bigger than 132mm.

Anti-condensation heater
Motors whose windings are at risk of condensation due to the climatic conditions, e.g. inactive motors in humid
atmospheres or motors that are subjected to widely fluctuating temperatures can be equipped with anti-condensation heaters (Option code: Q04),
2 auxiliary terminals in connection box are needed.” Anti-condensation heaters must be switched off during operation. When motor shut down, the heaters must be switched on.


Electrical data of Anti-condensation heater

Frame size

PowerW

VoltageV

80 ~ 90

20

220

100 ~ 112

30

220

132 ~ 160

40

220

180 ~ 200

50

220

225 ~ 280

60

220

315

80

220

355

100

220


Electro-Magnetic Brake
Disc type DC electro-magnetic brake can be attached to the 1TL0001 series of motors, the motors are suitable for all kinds of machines which require fast stop, accurate positioning and reciprocating operation.
1TL0001 Cast Iron Three-phase Asynchronous Motor

The technical data for the brakes

Frame size

(Nm) Static braking torque

(s) No-load braking time

(V) Brake voltage when switch is on the DC side

(W) Excitation power

ΔL1

(mm)

80

8

0.2

99

50

70

90

15

0.2

99

60

75

100

30

0.2

99

80

75

112

40

0.25

170

110

75

132

80

0.25

170

130

85

160

150

0.35

170

150

105

180

200

0.35

170

150

100

200

300

0.45

170

200

125

225

450

0.45

170

200

140

Electrical design

Rated Output
1TL0001 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation when operated at ambient temperature from -15 ºC to 40 ºC and at altitudes of up to 1000 m over sea.
Voltage and Frequency
IEC 60034-1 differentiates between Category A (combination of voltage deviation ±5 % and frequency deviation ±2
%) and Category B (combination of voltage deviation
±10 % and frequency deviation +3 % / -5 %) for voltage and frequency fluctuations. The motors can supply their rated torque in both Category A and B. In Category A, the temperature rise is approximately 10 K higher than during normal operation.

Standard 60034 - 1

Category A

Category B

Voltage deviation

±5 %

±10 %

Frequency deviation

±2 %

+3 % / -5 %

According to the standard, longer operation is not recommended for Category B.

Tolerance for electrical data
■Efficiencyηat
Prated ≤ 150 kW: - 0.15 x (1 – η) Prated > 150 kW: - 0.10 x (1 – η) With η being a decimal number
■Power factor - (1 – cosφ) / 6 Minimum absolute value: 0.02 Maximum absolute value: 0.07
■Slip ±20 % (for motors < 1 kW ±30 % is admissible)
■Locked-rotor current +20 %
■Locked-rotor torque -15 % to +25 %
■Breakdown torque -10 %
■Moment of inertia ±10 %

Converter fed application

1TL0001 motors are suitable for pumps, fans, compressors, texitle machine and mechanical machine applications where variable or constant speed is required.
The standard insulation of the 1TL0001 motors is designed such that operation is possible on the converter at mains voltage up to 460 V.
1TL0001 motors are capable for converter-fed operation with certain characteristics load, of which the load torque characteristics is referred in the following diagram:

1TL0001 Cast Iron Three-phase Asynchronous Motor

At rated output with converter fed operation, the motors will be used in temperature class 155 (F). To prevent damage
as a result of bearing currents, insulated bearings are recommended to be assembled for frame size 250 and above. Please inquire Siemens about the detailed information of insulated bearing.
By usage with admissible torque and below, the motor can be operated with self cooling; by usage over the admissible torque line, the motor with forced ventilation is needed.

At operating speeds above rated speed the noise and vibration levels increase and the bearing life time reduce. Attention should be paid to the re-greasing intervals and the grease service life.


The allowed maximum safe operating speed of 1TL0001 motors shows the diagram

Frame size

2 2 pole

4 4 pole

6 pole

 8 pole

Max.rpm

fmax

Max.rpm

fmax

Max.rpm

fmax

Max.rpm

fmax

80

5200

87

3600

120

2400

120

1800

120

90

5200

87

3600

120

2400

120

1800

120

100

5200

87

3600

120

2400

120

1800

120

112

5200

87

3600

120

2400

120

1800

120

132

4500

75

2700

90

2400

120

1800

120

160

4500

75

2700

90

2400

120

1800

120

180

4500

75

2700

90

2400

120

1800

120

200

4500

75

2300

77

1800

90

1400

93

225

3600

60

2300

77

1800

90

1400

93

250

3600

60

2300

77

1800

90

1400

93

280

3600

60

2300

77

1800

90

1400

93

315

3600

60

2300

77

1800

90

1400

93

355

3600

60

2300

77

1800

90

1400

93



Technical data for separately fan

Motor frame size

rated voltage

Rated frequency

Rated output

Current

Speed

ΔL

80

 

 

 

 

 

 

 

220D/380Y

50

30

0.14/0.08

2800

60

90

50

30

0.14/0.08

2800

75

100

50

52

0.21/0.12

2800

65

112

50

52

0.21/0.12

2800

75

132

50

45

0.35/0.2

1400

75

160

50

45

0.35/0.2

1400

45

180

50

120

1.04/0.6

1400

55

200

50

120

1.04/0.6

1400

60

225

50

120

1.04/0.6

1400

60

250

50

230

1.73/1.0

1400

60

280

50

230

1.73/1.0

1400

105

315

50

370

1.91/1.1

1250

95

355

50

550

2.18/1.26

1350

100

Note: The fan can be running with supply 210 ~ 240VD/360 ~ 420VY 50Hz, and also 220 ~ 260VD/380 ~ 480VY 60Hz. Other voltage supply, possible on request.


Technical data for fan motor

For some special application with external cooling facility, we can provide motor without fan and fan cover, the option code is F90. When motor without fan and fan cover, the length will decrease ∆ l.

motor frame size

Δl Length decrease of motor Δl

80

50

90

55

100

65

112

65

132

70

160

90

180

105

200

110

225

115

250

125

280

135

315

175

355

165


Technical data table

 Cast Iron Motors

Frame Size

Rate Output 50 Hz

Order No.

Rated Speed

 Efficiency at (50 HZ)

4/4 load

 Efficiency at (50 HZ)

3/4 load

Power factor

Rated current

Rated torque

Starting current

/Rated current

Starting torque/ Rated torque

Max torque

/ Rated torque


Moment of Inertia


IMB3

Weight

kW

rpm

%

%

 

A

Nm

Direct start to rated torque (current) multiples

kgm²

kg

 

3000rpm 2-pole

 

220VD / 380VY 50HZ

80M

0.75

1TL0001-0DA22-1 □□□

2795

77.4

78.5

0.84

1.75

2.6

5.6

2.4

2.4

0.00080

13.5

80M

1.1

1TL0001-0DA32-1 □□□

2835

79.6

80.6

0.84

2.50

3.7

6

2.8

3.2

0.0012

15.0

90S

1.5

1TL0001-0EA02-1 □□□

2890

81.3

81.7

0.84

3.35

5.0

6.5

2.4

3.1

0.0021

19.0

90L

2.2

1TL0001-0EA42-1 □□□

2890

83.2

83.7

0.85

4.75

7.3

7.2

2.6

3.5

0.0026

23

100L

3

1TL0001-1AA42-1 □□□

2885

84.6

85.1

0.84

6.4

9.9

7.5

4

4.5

0.0036

30

 

3000rpm 2-pole

 

380VD / 660VY 50HZ

112M

4

1TL0001-1BA23-3 □□□

2930

85.8

86.6

0.86

8.2

13.0

7.5

2.2

2.9

0.0064

37

132S

5.5

1TL0001-1CA03-3 □□□

2930

87

87.6

0.87

11.0

17.9

7.5

2.2

2.9

0.014

54

132S

7.5

1TL0001-1CA13-3 □□□

2930

88.1

88.8

0.89

14.5

24.4

7.5

2.3

2.9

0.017

59

160M

11

1TL0001-1DA23-3 □□□

2935

89.4

90.1

0.86

21.5

35.8

7.5

2.2

2.9

0.031

93

160M

15

1TL0001-1DA33-3 □□□

2935

90.3

91

0.86

29.5

48.8

7.5

2.4

3.2

0.038

103

160L

18.5

1TL0001-1DA43-3 □□□

2935

90.9

91.7

0.89

34.5

60.2

7.5

2.4

3.2

0.046

118

180M

22

1TL0001-1EA23-3 □□□

2935

91.3

91.8

0.87

42.0

71.6

7.6

2.5

3.2

0.072

151

200L

30

1TL0001-2AA43-3 □□□

2955

92

92.3

0.86

58

97.0

7.5

2.5

3.2

0.13

215

200L

37

1TL0001-2AA53-3 □□□

2955

92.5

92.8

0.88

69

119.6

7.5

2.5

3.2

0.15

240

225M

45

1TL0001-2BA23-3 □□□

2965

92.9

93.1

0.88

84

144.9

7.9

2.5

3.1

0.24

277

250M

55

1TL0001-2CA23-3 □□□

2970

93.2

93.2

0.88

102

176.9

7.5

2.5

3

0.42

309

280S

75

1TL0001-2DA03-3 □□□

2975

93.8

93.8

0.87

140

240.8

7.5

2.8

3

0.75

440

280M

90

1TL0001-2DA23-3 □□□

2978

94.1

94.1

0.87

167

288.6

7.5

3

3.1

0.88

520

315S

110

1TL0001-3AA03-3 □□□

2982

94.3

94.3

0.90

197

352.3

7.5

2.2

2.6

1.4

750

315M

132

1TL0001-3AA23-3 □□□

2982

94.6

94.6

0.91

235

422.7

7.5

2.3

2.9

1.7

905

315L

160

1TL0001-3AA53-3 □□□

2982

94.8

95.1

0.92

280

512.4

7.5

2.5

2.8

1.9

945

315L

185

1TL0001-3AA63-3 □□□

2982

95

95.3

0.92

320

592.5

7.5

2.5

2.8

2.3

1060

315L

200

1TL0001-3AA73-3 □□□

2982

95

95.3

0.92

350

640.5

7.5

2.5

2.8

2.3

1070

355M

220

1TL0001-3BA23-3 □□□

2985

95.0

94.7

0.90

390

704

7.0

2.0

2.6

2.5

1400

355M

250

1TL0001-3BA33-3 □□□

2985

95.0

94.7

0.90

445

800

7.4

2.3

2.8

2.7

1460

355L

280

1TL0001-3BA53-3 □□□

2985

95.0

95.1

0.91

490

896

7.0

2.2

2.6

3.0

1540

355L

315

1TL0001-3BA63-3 □□□

2985

95.0

95.0

0.91

550

1008

7.4

2.5

2.8

3.3

1670

Note: 1) About the code of other voltage and frequency, winding protection and connection box position, please refer to Orde No. in page 14.
         2) Noise value is only applicable to the direct power supply of the motor in 50Hz power supply and the condition of no-load operation, the tolerance is +3dB. Only suitable for cooling method IC416(Option code F70), IC418(Option code F70) motor.


Technical data table
Cast Iron Motors

Frame Size

Rate Output 50 Hz

Order No.

Rated Speed

 Efficiency at (50 HZ)

4/4 load

 Efficiency at (50 HZ)

3/4 load

Power factor

Rated current

Rated torque

Starting current

/Rated current

Starting torque/ Rated torque

Max torque

/ Rated torque

Moment of Inertia

IMB3

Weight

kW

rpm

%

%

 

A

Nm

Direct start to rated torque (current) multiples

kgm²

kg

 

1500rpm 4-pole

 

220VD / 380VY 50HZ

80M

0.55

1TL0001-0DB22-1 □□□

1425

74.0

74.7

0.8

1.40

3.7

6

2

2.7

0.0021

14.0

80M

0.75

1TL0001-0DB32-1 □□□

1440

79.6

79.6

0.75

1.90

5.0

6.5

2.8

3.5

0.0027

15.5

90S

1.1

1TL0001-0EB02-1 □□□

1440

81.4

81.4

0.75

2.75

7.3

7

2.8

3.5

0.0041

20

90L

1.5

1TL0001-0EB42-1 □□□

1435

82.8

82.8

0.76

3.60

9.9

7

3

3.8

0.0047

23

100L

2.2

1TL0001-1AB42-1 □□□

1435

84.3

85

0.79

5.0

14.6

7

3

3.2

0.0081

30

100L

3

1TL0001-1AB52-1 □□□

1435

85.5

86.3

0.79

6.7

20.0

7

3

3.2

0.010

33

 

1500rpm 4-pole

 

380VD / 660VY 50HZ

112M

4

1TL0001-1BB23-3 □□□

1445

86.6

87.1

0.79

8.9

26.4

7.1

2.7

3.1

0.011

42

132S

5.5

1TL0001-1CB03-3 □□□

1460

87.7

88.2

0.79

12.1

36.0

7.5

2.5

3.1

0.021

58

132M

7.5

1TL0001-1CB23-3 □□□

1460

88.7

89.4

0.82

15.7

49.1

7.7

2.7

3.2

0.029

72

160M

11

1TL0001-1DB23-3 □□□

1465

89.8

90.4

0.84

22.0

71.7

7.5

2.5

3.1

0.051

99

160L

15

1TL0001-1DB43-3 □□□

1465

90.6

91.3

0.85

29.5

97.8

7.8

2.7

3.2

0.066

120

180M

18.5

1TL0001-1EB23-3 □□□

1465

91.2

91.8

0.85

36.5

120.6

7.3

2.5

3.2

0.13

163

180L

22

1TL0001-1EB43-3 □□□

1465

91.6

92.3

0.85

43.0

143.4

7.3

2.4

3.2

0.14

182

200L

30

1TL0001-2AB43-3 □□□

1470

92.3

92.9

0.85

58

194.9

7.3

2.7

3.2

0.22

227

225S

37

1TL0001-2BB03-3 □□□

1475

92.7

93.2

0.86

71

239.6

7.3

2.7

3.2

0.45

262

225M

45

1TL0001-2BB23-3 □□□

1475

93.1

93.5

0.87

84

291.4

7.3

2.7

3.2

0.51

284

250M

55

1TL0001-2CB23-3 □□□

1480

93.5

93.9

0.86

104

354.9

7.5

3.1

3.5

0.80

330

280S

75

1TL0001-2DB03-3 □□□

1485

94

94.3

0.87

139

482.3

7.5

2.7

3.1

1.4

480

280M

90

1TL0001-2DB23-3 □□□

1485

94.2

94.3

0.87

167

578.8

7.5

2.7

3.1

1.5

555

315S

110

1TL0001-3AB03-3 □□□

1488

94.5

94.5

0.86

205

706.0

7.3

2.8

2.9

2.2

750

315M

132

1TL0001-3AB23-3 □□□

1486

94.7

94.7

0.88

240

848.3

7.3

2.5

2.7

2.5

880

315L

160

1TL0001-3AB53-3 □□□

1488

94.9

94.9

0.88

290

1026.9

7.4

3

2.9

3.0

965

315L

185

1TL0001-3AB63-3 □□□

1488

95.1

95.1

0.88

335

1187.3

7.4

3

3

3.6

1060

315L

200

1TL0001-3AB73-3 □□□

1488

95.1

95.1

0.88

365

1283.6

7.4

3

3

3.7

1080

355M

220

1TL0001-3BB23-3 □□□

1490

95.1

95.2

0.89

395

1411

6.9

1.7

2.5

4.9

1580

355M

250

1TL0001-3BB33-3 □□□

1490

95.1

95.2

0.89

450

1604

6.9

1.8

2.5

5.0

1630

355L

280

1TL0001-3BB53-3 □□□

1490

95.1

95.3

0.89

500

1795

7.0

1.9

2.7

5.3

1680

355L

315

1TL0001-3BB63-3 □□□

1490

95.1

95.2

0.89

570

2019

7.0

1.9

2.7

5.7

1760

Note: 1) About the code of other voltage and frequency, winding protection and connection box position, please refer to Orde No. in page 14.
2) Noise value is only applicable to the direct power supply of the motor in 50Hz power supply and the condition of no-load operation, the tolerance is +3dB. Only suitable for cooling method IC416(Option code F70), IC418(Option code F70) motor.

Technical data table
Cast Iron Motors

Frame Size

Rate Output 50 Hz

Order No.

Rated Speed

 Efficiency at (50 HZ)

4/4 load

 Efficiency at (50 HZ)

3/4 load

Power factor

Rated current

Rated torque

Starting current

/Rated current

Starting torque/ Rated torque

Max torque

/ Rated torque

Moment of Inertia

IMB3

Weight

kW

rpm

%

%

 

A

Nm

Direct start to rated torque (current) multiples

kgm²

kg

 

1000rpm 6-pole

 

220VD / 380VY 50HZ

80M

0.55

1TL0001-0DC32-1 □□□

895

71

72

0.76

1.55

5.9

4.5

2.3

2.3

0.0028

16.0

90S

0.75

1TL0001-0EC02-1 □□□

935

75.9

76.5

0.71

2.10

7.7

5

2.1

2.6

0.0038

20

90L

1.1

1TL0001-0EC42-1 □□□

945

78.1

78.1

0.71

3.00

11.1

5.5

2.4

2.8

0.0046

24

100L

1.5

1TL0001-1AC42-1 □□□

945

79.8

80.1

0.74

3.85

15.2

5.5

2.4

2.9

0.0086

31

112M

2.2

1TL0001-1BC22-1 □□□

950

81.8

82.5

0.73

5.6

22.1

5.5

2.6

3.3

0.012

41

132S

3

1TL0001-1CC02-1 □□□

960

83.3

84.3

0.73

7.5

29.8

6

2

2.2

0.019

54

 

1000rpm 6-pole

 

380VD / 660VY 50HZ

132M

4

1TL0001-1CC23-3 □□□

960

84.6

85.4

0.73

9.8

39.8

6.2

2.2

2.5

0.024

65

132M

5.5

1TL0001-1CC33-3 □□□

960

86

86.6

0.75

13.0

54.7

6.4

2.4

2.6

0.031

73

160M

7.5

1TL0001-1DC23-3 □□□

975

87.2

87.9

0.77

17.0

73.5

6.4

2.1

2.6

0.1069

103

160L

11

1TL0001-1DC43-3 □□□

975

88.7

89.4

0.78

24.0

108

6.4

2.1

2.6

0.14

120

180L

15

1TL0001-1EC43-3 □□□

975

89.7

90.4

0.78

32.5

146.9

6.5

2.3

3

0.18

163

200L

18.5

1TL0001-2AC43-3 □□□

975

90.4

91

0.81

38.5

181.2

6.5

2.3

2.8

0.27

210

200L

22

1TL0001-2AC53-3 □□□

975

90.9

91.4

0.82

45.0

215.5

6.5

2.3

2.8

0.32

228

225M

30

1TL0001-2BC23-3 □□□

980

91.7

92.3

0.83

60

292.3

6.5

2.2

2.8

0.62

282

250M

37

1TL0001-2CC23-3 □□□

982

92.2

92.8

0.83

73

359.8

7

2.5

2.8

0.91

332

280S

45

1TL0001-2DC03-3 □□□

985

92.7

93.3

0.85

87

436.3

7.5

2.5

2.8

1.2

410

280M

55

1TL0001-2DC23-3 □□□

986

93.1

93.7

0.85

106

532.7

7.5

2.5

2,8

1.5

485

315S

75

1TL0001-3AC03-3 □□□

986

93.7

94.3

0.85

143

726.4

7.3

2.3

2.8

2.3

690

315M

90

1TL0001-3AC23-3 □□□

986

94

94.5

0.85

171

871.7

7.3

2.3

2.8

2.8

830

315L

110

1TL0001-3AC53-3 □□□

988

94.3

94.7

0.86

205

1063.3

7.5

2.4

2.8

3.9

965

315L

132

1TL0001-3AC63-3 □□□

988

94.6

95

0.86

245

1275.9

7.5

2.5

3

4.3

1010

355M

160

1TL0001-3BC23-3 □□□

991

94.8

95.4

0.87

295

1542

7.0

2.4

2.2

8.9

1610

355M

185

1TL0001-3BC33-3 □□□

991

95.0

95.5

0.87

340

1783

7.1

2.6

2.6

9.4

1750

355M

200

1TL0001-3BC43-3 □□□

991

95.0

95.5

0.87

370

1930

7.1

2.6

2.6

10.5

1750

355L

220

1TL0001-3BC53-3 □□□

991

95.0

95.5

0.87

405

2121

7.6

2.6

2.6

11.5

1850

355L

250

1TL0001-3BC63-3 □□□

992

95.0

95.4

0.87

460

2408

7.8

2.8

2.7

12.9

1930

Note:
1) About the code of other voltage and frequency, winding protection and connection box position, please refer to Orde No. in page 14.
2) Noise value is only applicable to the direct power supply of the motor in 50Hz power supply and the condition of no-load operation, the tolerance is +3dB. Only suitable for cooling method IC416(Option code F70), IC418(Option code F70) motor.

Technical data table

Cast Iron Motors

Frame Size

Rate Output 50 Hz

Order No.

Rated Speed

 Efficiency at (50 HZ)

4/4 load

 Efficiency at (50 HZ)

3/4 load

Power factor

Rated current

Rated torque

Starting current

/Rated current

Starting torque/ Rated torque

Max torque

/ Rated torque

Moment of Inertia

IMB3

Weight

kW

rpm

%

%

 

A

Nm

Direct start to rated torque (current) multiples

kgm²

kg

 

750rpm 8-pole

 

220VD/380VY 50HZ

132S

2.2

1TL0001-1CD02-1 □□□

725

77.6

78.3

0.70

6.2

29.2

4.6

1.9

3

0.022

79

132M

3

1TL0001-1CD22-1 □□□

720

80.0

80.3

0.75

7.6

40

4.8

2

3

0.037

79

 

750rpm 8-pole

 

380VD/660VY 50HZ

160M

4

1TL0001-1DD23-3 □□□

730

81.9

82.1

0.66

11.2

52

4.9

1.8

2.8

0.051

97

160M

5.5

1TL0001-1DD33-3 □□□

720

83.8

84.1

0.68

14.7

73

4.6

1.5

2.0

0.051

105

160L

7.5

1TL0001-1DD43-3 □□□

730

85.3

85.5

0.67

19.9

99

5

1.7

2.3

0.067

121

180L

11

1TL0001-1ED43-3 □□□

715

86.9

87.2

0.75

25.5

147

5

2.1

2.6

0.20

163

200L

15

1TL0001-2AD53-3 □□□

715

88.0

88.1

0.78

33.0

200

6

2.3

2.9

0.35

233

225S

18.5

1TL0001-2BD03-3 □□□

729

88.6

88.9

0.77

41.0

240

6.6

2.4

3

0.48

246

225M

22

1TL0001-2BD23-3 □□□

728

89.1

89.4

0.79

47.5

290

7

2.7

2.8

0.56

286

250M

30

1TL0001-2CD23-3 □□□

732

89.8

90.0

0.81

63

390

6.3

2.2

2.7

0.94

330

280S

37

1TL0001-2DD03-3 □□□

736

90.3

90.4

0.78

80

480

6.5

2.5

2.7

1.2

395

280M

45

1TL0001-2DD23-3 □□□

738

90.7

90.8

0.79

94

582

6.3

2.2

2.7

1.5

479

315S

55

1TL0001-3AD03-3 □□□

740

91.0

91.1

0.81

113

710

6.2

2

2.9

2.1

665

315M

75

1TL0001-3AD23-3 □□□

738

91.6

92.1

0.81

154

970

6.7

2.2

2.5

2.6

845

315L

90

1TL0001-3AD53-3 □□□

738

91.9

92.5

0.83

179

1165

5.9

1.8

2.3

3.3

890

315L

110

1TL0001-3AD63-3 □□□

741

92.3

92.6

0.83

220

1418

7.1

2.3

3

4.2

1040

355M

132

1TL0001-3BD23-3 □□□

743

92.6

93.2

0.81

265

1699

7.1

2.2

2.4

8.2

1530

355M

160

1TL0001-3BD33-3 □□□

742

93.0

93.5

0.82

320

2059

7.1

2.2

2.4

9.6

1650

355L

185

1TL0001-3BD53-3 □□□

742

93.3

93.9

0.84

360

2382

7.1

2.0

2.1

11.4

1820

355L

200

1TL0001-3BD63-3 □□□

742

93.5

94.0

0.84

385

2576

7.4

2.0

2.1

12.7

1930

Note:

1) About the code of other voltage and frequency, winding protection and connection box position, please refer to Orde No. in page 14.

2) Noise value is only applicable to the direct power supply of the motor in 50Hz power supply and the condition of no-load operation, the tolerance is +3dB. Only suitable for cooling method IC416(Option code F70), IC418(Option code F70) motor.


Options

Motor order code

Option Code

Description

Application Scope

Voltages and frequency

 

 

 

1TL0001- □□□□ 9-0 □□□ -Z

M2A2)17

220VD/380VY 60Hz50Hz power output

FS80 ~ 355

M2B3)17

380VD/660VY 60Hz50Hz power output

FS80 ~ 355

M2C2)17)

440VY 60Hz50Hz power output

FS80 ~ 280

M2D3)17

440VD 60Hz50Hz power output

FS80 ~ 355

M2E2)17)

460VY 60Hz50Hz power output

FS80 ~ 280

M2F3)17

460VD 60Hz50Hz power output

FS80 ~ 355

Windings and insulation

N0118

Temperature class 155 (F), used according to 155 (F), with service factor (SF1.15)

FS80 ~ 355

N10

Temperature class 180H

FS80 ~ 355

Q044

Anti-condensation heater for 220 VAC (spaces heater)

FS80 ~ 355

Motor connection box

R10 5)

Rotation of the connection box through 90º, entry from DE

FS80 ~ 355

R11 6)

Rotation of the connection box through 90º, entry from NDE

FS80 ~ 355

R12

Rotation of the connection box through 180º

FS80 ~ 355

H04

external earthing

FS80 ~ 280

X07

cast iron connection box

FS80 ~ 355

X47

Connection boxes of the motors include 2 self-locking cable gland

FS112 ~ 355

 Bearings

Q72

Installation of 2PT100 screw-in resistance thermometers for bearing

FS180 ~ 355

L80

SKF Bearing

FS80 ~ 355

L81

Other imported brand bearings

FS80 ~ 355

L20

Located bearing at DE

FS80 ~ 160

L227)

Increased cantilever forces

FS100 ~ 355

Mechanical design and degrees of protection

X178)9)

Second standard shaft extension

FS80 ~ 355

P8010)

Full circle flange

FS80 ~ 315

1) Order No. supplement Z with option code when ordering.
2) Only applicable to the motor whose power is 3kW and below.
3) Only applicable to the motor whose power is 3kW and above.
4) When choose these options, the connection boxes will be changed to cast iron shell.
5) Not applicable to the FS80~10 flange mounted motors, and can't be used with the option H08.
6) Not applicable to the outlet on top.
7) Cast iron motor exclude FS160.
8) H00、F70 can't be used with this option.
9) Second standard shaft extension on NDE is shown in the dimension drawings.
10) Not applicable to the FS180、200、225 and 280 motors, these motors include the full circle flange.



Home> Products> LV 3PH Asynchronous Motor> Cast Iron LV 3PH Asynchronous Motor> BEIDE7.5KW 1TL0001 Cast Iron Three-phase Asynchronous Motor
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send