The aluminum frame LV 3PH asynchronous motor is a popular choice for many applications due to its high efficiency, reliability, and low maintenance requirements. It is also a cost-effective option compared to other types of motors. The motor is...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 0.75KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 1.1KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 4KW 1TL0303 Al Frame Three-phase Asynchronous Motor 4KW 1TL0303 Three-phase Asynchronous Motor.4KW Al Frame Low-voltage Asynchronous Motor Rated output:0.55 ~ 18.5 kW Frame size:80 ~ 160.Voltage and Frequency:support multiple voltage and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 3KW 1TL0303 Al Frame Three-phase Asynchronous Motor 3KW 1TL0303 Three-phase Asynchronous Motor.3KW Al Frame Low-voltage Asynchronous Motor Rated output:0.55 ~ 18.5 kW Frame size:80 ~ 160.Voltage and Frequency:support multiple voltage and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 2.2KW 1TL0303 Al Frame Three-phase Asynchronous Motor 2.2KW 1TL0303 Three-phase Asynchronous Motor.2.2KW Al Frame Low-voltage Asynchronous Motor Rated output:0.55 ~ 18.5 kW Frame size:80 ~ 160.Voltage and Frequency:support multiple voltage and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 15KW 1TL0303 Al Frame Three-phase Asynchronous Motor 15KW Al Frame Three-Phase Asynchronous Motor Electrical design Rated Output 1TL0 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation when...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 11KW 1TL0303 Al Frame Three-phase Asynchronous Motor 11KW Al Frame Three-Phase Asynchronous Motor Electrical design Rated Output 1TL0 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation when...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 7.5KW 1TL0303 Al Frame Three-phase Asynchronous Motor 7.5KW Al Frame Three-Phase Asynchronous Motor Electrical design Rated Output 1TL0 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 5.5KW 1TL0303 Al Frame Three-phase Asynchronous Motor 5.5KW Al Frame Three-Phase Asynchronous Motor Electrical design Rated Output 1TL0 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 22KW 1TL0303 Al Frame Three-phase Asynchronous Motor At rated output with converter fed operation, the motors will be used in temperature class 155 (F). To prevent damage as a result of bearing currents, insulated bearings are recommended to...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 30KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 55KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 75KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 45KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 37KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 110KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
BEIDE 90KW 1TL0303 Al Frame Three-phase Asynchronous Motor 1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and...
Brand:Beide
Transportation:Ocean
Place of Origin:China
1TL0 aluminum shell series low-voltage three-phase asynchronous motor technical parameters: Rated power: 0.55~18.5 kW Frame size: 80~160 Voltage and frequency: Support multiple voltages and frequencies Cooling method: Standard IC411, IC416 optional...
As one of Siemens main low-voltage motor production facilities worldwide, SSML uses the knowledge and experience of more than 100 years in motor design and manufacturing, owns the advanced manufacture equipment and process, adopts the SIEMENS modern management model , and implements comprehensive quality control according to ISO9001 2015. SSML will continuously serve customers with high quality products and good service.
Bearing system
1TL0 series AL frame motors are supplied with the sealed ball bearing as standard. And the floating bearings are assembled.
The standard bearing can endure a maximum cantilever force, the increased cantilever bearing design (Option code: L22) should be considered.
Bearing Assignment
Frame size |
Pole |
Standard design |
Increased cantilever-bearing (Option code:L22) |
||||
DE bearing |
NDE bearing (Horizontal mounting) |
NDE bearing (Vertical mounting) |
DE bearing |
NDE bearing (Horizontal mounting) |
NDE bearing (Vertical mounting) |
||
80 |
2, 4, 6 |
6204 2RZ C3 |
6204 2RZ C3 |
6204 2RZ C3 |
- |
- |
- |
90 |
2, 4, 6 |
6205 2RZ C3 |
6205 2RZ C3 |
6205 2RZ C3 |
- |
- |
- |
100 |
2, 4, 6 |
6206 2RZ C3 |
6206 2RZ C3 |
6206 2RZ C3 |
6306 2RZ C3 |
6206 2RZ C3 |
6206 2RZ C3 |
112 |
2, 4, 6 |
6206 2RZ C3 |
6206 2RZ C3 |
6206 2RZ C3 |
6306 2RZ C3 |
6206 2RZ C3 |
6206 2RZ C3 |
132 |
2, 4, 6, 8 |
6208 2RZ C3 |
6208 2RZ C3 |
6208 2RZ C3 |
6308 2RZ C3 |
6208 2RZ C3 |
6208 2RZ C3 |
160 |
2 |
6209 2RZ C3 |
6209 2RZ C3 |
6209 2RZ C3 |
6309 2RZ C3 |
6209 2RZ C3 |
6209 2RZ C3 |
4, 6, 8 |
Note: DE Driven end
NDE Non driven end
-Not possible
O.R. Possible on request
Grease life (Horizontal installation)
Frame size |
Poles |
Grease lifetime up to CT 40 ºC 1) |
Grease for permanent lubrication bearing |
||
80 ~ 160 |
2,4,6,8 |
20000 (or) 40000 2) |
Note:
1) If the coolant temperature is increased by 10 K, the grease lifetime and regreasing interval are halved.
2) 40000 h apply to horizontally installed motors with coupling output without additional axial loads.
■When motor runs beyond the rated speed, the increase of motor vibration will result in the extra radial and axial force on bearing. This will reduce the life of bearing;
■When the motor vibration increase due to the environment
or other equipment, the bearing also will endure more radial and axial force. This also will reduce the life of bearing;
■If the coolant temperature is increased by 10 ºC, the grease lifetime and regreasing interval is halved.
Connection boxes technical data
Frame size |
Contact screw thread |
Outer cable diameter (sealing range)(mm)
|
Cable entry size |
80 ~ 100 |
M4 |
10~14 |
M24 x 1.5 |
112 ~ 132 |
M5 |
13~18 |
M27 x 2 + M27 x 2 |
160 |
M5 |
18~25 |
M36 x 2 + M36 x 2 |
Vibration
1TL0 rotors are dynamically balanced to severity grade A using a half key.
Table below contains the effective vibration values for unloaded motors.
Vibration Grade |
Frame size (mm) |
56 ≤ FS ≤ 132 |
H>132 |
||
Mounting |
Vibration displacement/um |
Vibration velocity/(mm/s) |
Vibration displacement/um |
Vibration velocity/(mm/s) |
|
A |
Free suspension |
45 |
2.8 |
45 |
2.8 |
Rigid mounting |
- |
- |
37 |
2.3 |
|
2.81) |
|||||
B |
Free suspension |
18 |
1.1 |
29 |
1.8 |
Rigid mounting |
- |
- |
24 |
1.5 |
|
1.81) |
Note:
1) The level are vibration velocity limit when the twice line frequency vibration level is dominant defined by GB/T 10068-2020, for 2p motors that frame size bigger than 132mm.
Anti-condensation heater
Motors whose windings are at risk of condensation due to the climatic conditions, e.g. inactive motors in humid atmospheres or motors that are subjected to widely fluctuating temperatures can be equipped with anti-condensation heaters (Option code: Q04)
2 auxiliary terminals in connection box are needed.” Anti- condensation heaters must be switched off during operation. When motor shut down, the heaters must be switched on.
Electrical data of Anti-condensation heater
Frame size |
Power(W) |
Voltage(V) |
80 ~ 90 |
20 |
220 |
100 ~ 112 |
30 |
220 |
132 ~ 160 |
40 |
220 |
Electro-Magnetic Brake
Disc type DC electro-magnetic brake can be attached to the 1TL0 series of motors, the motors are suitable for all kinds of machines which require fast stop, accurate positioning and reciprocating operation.
The technical data for the brakes
Frame size |
(Nm) Static braking torque |
(s) No-load braking time |
(V) Brake voltage when switch is on the DC side |
(W) Excitation power |
ΔL1 (mm) |
80 |
8 |
0.2 |
99 |
50 |
70 |
90 |
15 |
0.2 |
99 |
60 |
75 |
100 |
30 |
0.2 |
99 |
80 |
75 |
112 |
40 |
0.25 |
170 |
110 |
75 |
132 |
80 |
0.25 |
170 |
130 |
85 |
160 |
150 |
0.35 |
170 |
150 |
105 |
Electrical design
Rated Output
1TL0 motors rated output powers means that the motor runs under continuous duty S1 (IEC 60034 - 1) operation when operated at ambient temperature from -15 ºC to 40 ºC and at altitudes of up to 1000 m over sea.
Voltage and Frequency
IEC 60034-1 differentiates between Category A (combination of voltage deviation ±5 % and frequency deviation ±2
%) and Category B (combination of voltage deviation
±10 % and frequency deviation +3 % / -5 %) for voltage and frequency fluctuations. The motors can supply their rated torque in both Category A and B. In Category A, the temperature rise is approximately 10 K higher than during normal operation.
Standard 60034 - 1 |
Category A |
类别Category B |
Voltage deviation |
±5 % |
±10 % |
Frequency deviation |
±2 % |
+3 % / -5 % |
According to the standard, longer operation is not recommended for Category B. |
Tolerance for electrical data
■Efficiencyηat
1TL0 motors are suitable for pumps, fans, compressors, texitle machine and mechanical machine applications where variable or constant speed is required.
The standard insulation of the 1TL0 motors is designed such that operation is possible on the converter at mains voltage up to 460 V.
1TL0 motors are capable for converter-fed operation with certain characteristics load, of which the load torque characteristics is referred in the following diagram:
At rated output with converter fed operation, the motors will be used in temperature class 155 (F). To prevent damage as a result of bearing currents, insulated bearings are recommended to be assembled for frame size 250 and above. Please inquire Siemens about the detailed information of insulated bearing.
By usage with admissible torque and below, the motor can be operated with self cooling; by usage over the admissible torque line, the motor with forced ventilation is needed.
At operating speeds above rated speed the noise and vibration levels increase and the bearing life time reduce. Attention should be paid to the re-greasing intervals and the grease service life.
The allowed maximum safe operating speed of 1TL0 motors shows the diagram
Frame size |
2 pole |
4 pole |
6 pole |
8 pole |
||||
Max.rpm |
fmax |
Max.rpm |
fmax |
Max.rpm |
fmax |
Max.rpm |
fmax |
|
80 |
5200 |
87 |
3600 |
120 |
2400 |
120 |
1800 |
120 |
90 |
5200 |
87 |
3600 |
120 |
2400 |
120 |
1800 |
120 |
100 |
5200 |
87 |
3600 |
120 |
2400 |
120 |
1800 |
120 |
112 |
5200 |
87 |
3600 |
120 |
2400 |
120 |
1800 |
120 |
132 |
4500 |
75 |
2700 |
90 |
2400 |
120 |
1800 |
120 |
160 |
4500 |
75 |
2700 |
90 |
2400 |
120 |
1800 |
120 |
Technical data for separately fan
Technical data for separately fan
Motor frame size |
(V) rated voltage |
(Hz) Rated frequency |
(W) Rated output |
(A) Current |
(r/min) Speed |
ΔL |
80 |
220D/380Y |
50 |
30 |
0.14/0.08 |
2800 |
60 |
90 |
220D/380Y |
50 |
30 |
0.14/0.08 |
2800 |
75 |
100 |
220D/380Y |
50 |
52 |
0.21/0.12 |
2800 |
65 |
112 |
220D/380Y |
50 |
52 |
0.21/0.12 |
2800 |
75 |
132 |
220D/380Y |
50 |
45 |
0.35/0.2 |
1400 |
75 |
160 |
220D/380Y |
50 |
45 |
0.35/0.2 |
1400 |
45 |
Note: The fan can be running with supply 210 ~ 240VD/360 ~ 420VY 50Hz, and also 220 ~ 260VD/380 ~ 480VY 60Hz. Other voltage supply, possible on request.
Technical data for fan motor
For some special application with external cooling facility, we can provide motor without fan and fan cover, the option code is F90. When motor without fan and fan cover, the length will decrease ∆ l.
motor frame size |
Length decrease of motor Δl |
80 |
50 |
90 |
60 |
100 |
70 |
112 |
65 |
132 |
75 |
160 |
90 |
Technical data table
Al Frame Motors IE3
Frame Size |
(50Hz) Rated Output (50Hz) |
Motor Type |
Order No. |
Rated Speed |
Effeciency is in accordance with the effeciency level 3 of GB18613-2020 |
Rated torque |
Starting Current/ Rated current |
Starting torque/ Rated torque |
Max torque/ Reted torque |
Moment of intertia |
Weight IMB3 |
Noise |
|||
Effeciency at (50Hz) 4/4 load
|
Effeciency at (50Hz) 3/4 load
|
Power factor |
Rated current |
||||||||||||
kW |
|
rpm |
% |
% |
|
A |
Nm |
ILR/Irated |
TLR/Trated |
Tmax/Trated |
kgm² |
kg |
LpfA |
||
|
3000rpm 2- pole |
||||||||||||||
|
220VD/380VY 50HZ |
||||||||||||||
80M |
0.75 |
0AV3082A |
1TL0303-0DA22-1 □□□ |
2835 |
80.7 |
82.9 |
0.86 |
1.64 |
2.5 |
6.0 |
2.4 |
3.0 |
0.00208 |
11.5 |
51 |
80M |
1.1 |
0AV3083A |
1TL0303-0DA32-1 □□□ |
2850 |
82.7 |
84.0 |
0.83 |
2.45 |
3.7 |
6.5 |
2.6 |
3.4 |
0.00154 |
13.5 |
51 |
90S |
1.5 |
0AV3090A |
1TL0303-0EA02-1 □□□ |
2870 |
84.2 |
84.8 |
0.86 |
3.15 |
5.0 |
6.5 |
2.0 |
3.0 |
0.00276 |
17.0 |
58 |
90L |
2.2 |
0AV3094A |
1TL0303-0EA42-1 □□□ |
2890 |
85.9 |
87.2 |
0.88 |
4.4 |
7.3 |
7.5 |
2.8 |
3.6 |
0.00356 |
22 |
58 |
100L |
3 |
0AV3104A |
1TL0303-1AA42-1 □□□ |
2865 |
87.1 |
88.3 |
0.87 |
6 |
10.0 |
7.8 |
3.3 |
3.6 |
0.00462 |
28 |
62 |
|
3000rpm 2- pole |
||||||||||||||
|
380VD/660VY 50HZ |
||||||||||||||
112M |
4 |
0AV3112A |
1TL0303-1BA23-3 □□□ |
2915 |
88.1 |
89.6 |
0.90 |
7.7 |
13.1 |
7.8 |
2.6 |
3.6 |
0.0088 |
35 |
65 |
132S |
5.5 |
0AV3130A |
1TL0303-1CA03-3 □□□ |
2930 |
89.2 |
90.2 |
0.89 |
10.5 |
17.9 |
7.5 |
2.3 |
3.6 |
0.0185 |
47 |
67 |
132S |
7.5 |
0AV3131A |
1TL0303-1CA13-3 □□□ |
2930 |
90.1 |
91.5 |
0.90 |
14.1 |
24.4 |
7.5 |
2.3 |
3.6 |
0.0232 |
54 |
67 |
160M |
11 |
0AV3162A |
1TL0303-1DA23-3 □□□ |
2935 |
91.2 |
92.0 |
0.89 |
20.5 |
35.8 |
7.5 |
2.3 |
3.4 |
0.0390 |
79 |
69 |
160M |
15 |
0AV3163A |
1TL0303-1DA33-3 □□□ |
2935 |
91.9 |
92.6 |
0.89 |
28 |
48.8 |
7.5 |
2.4 |
3.4 |
0.0472 |
89 |
69 |
160L |
18.5 |
0AV3164A |
1TL0303-1DA43-3 □□□ |
2935 |
92.4 |
93.0 |
0.89 |
34 |
60.2 |
7.8 |
2.4 |
3.4 |
0.0577 |
103 |
69 |
|
1500rpm 4- pole |
||||||||||||||
|
220VD/380VY 50HZ |
||||||||||||||
80M |
0.55 |
0AV3082B |
1TL0303-0DB22-1 □□□ |
1440 |
80.8 |
81.8 |
0.76 |
1.36 |
3.6 |
5.5 |
2.2 |
3.2 |
0.00216 |
12.5 |
45 |
80M |
0.75 |
0AV3083B |
1TL0303-0DB32-1 □□□ |
1440 |
82.5 |
82.9 |
0.75 |
1.84 |
5.0 |
6.0 |
2.6 |
3.7 |
0.00250 |
13.5 |
45 |
90S |
1.1 |
0AV3090B |
1TL0303-0EB02-1 □□□ |
1430 |
84.1 |
85.1 |
0.79 |
2.5 |
7.3 |
6.5 |
2.7 |
3.7 |
0.00389 |
17.0 |
47 |
90L |
1.5 |
0AV3094B |
1TL0303-0EB42-1 □□□ |
1440 |
85.3 |
86.0 |
0.79 |
3.4 |
9.9 |
6.5 |
2.8 |
3.8 |
0.00499 |
21 |
47 |
100L |
2.2 |
0AV3104B |
1TL0303-1AB42-1 □□□ |
1440 |
86.7 |
87.1 |
0.81 |
4.75 |
14.6 |
8.3 |
3.0 |
4.0 |
0.01125 |
30 |
52 |
100L |
3 |
0AV3105B |
1TL0303-1AB52-1 □□□ |
1440 |
87.7 |
88.1 |
0.81 |
6.4 |
19.9 |
8.3 |
3.0 |
4.0 |
0.01313 |
34 |
52 |
|
1500rpm 4- pole |
||||||||||||||
|
380VD/660VY 50HZ |
||||||||||||||
112M |
4 |
0AV3112B |
1TL0303-1BB23-3 □□□ |
1450 |
88.6 |
89.6 |
0.81 |
8.5 |
26.3 |
8.3 |
3.7 |
4.6 |
0.0149 |
39 |
53 |
132S |
5.5 |
0AV3130B |
1TL0303-1CB03-3 □□□ |
1455 |
89.6 |
90.9 |
0.84 |
11.1 |
36.1 |
7.8 |
2.4 |
3.8 |
0.0285 |
53 |
59 |
132M |
7.5 |
0AV3132B |
1TL0303-1CB23-3 □□□ |
1455 |
90.4 |
91.7 |
0.85 |
14.8 |
49.2 |
7.8 |
2.4 |
3.8 |
0.0356 |
64 |
59 |
160M |
11 |
0AV3162B |
1TL0303-1DB23-3 □□□ |
1465 |
91.4 |
92.4 |
0.86 |
21.5 |
71.7 |
7.8 |
2.6 |
3.8 |
0.0648 |
85 |
61 |
160L |
15 |
0AV3164B |
1TL0303-1DB43-3 □□□ |
1465 |
92.1 |
92.9 |
0.86 |
29 |
97.8 |
8.2 |
2.6 |
3.8 |
0.0811 |
102 |
61 |
Note:
1) About the code of other voltage and frequency, winding protection and connection box position, please refer to Orde No. in page 13.
2) Noise value is only applicable to the direct power supply of the motor in 50Hz power supply and the condition of no-load operation, the tolerance is +3dB.
Technical data table
Al Frame Motors IE3
Frame Size |
(50Hz) Rated Output (50Hz) |
Motor Type |
Order No. |
Rated Speed |
Effeciency is in accordance with the effeciency level 3 of GB18613-2020 |
Rated torque |
Starting Current/ Rated current |
Starting torque/ Rated torque |
Max torque/ Reted torque |
Moment of intertia |
Weight IMB3 |
Noise |
|||
Effeciency at (50Hz) 4/4 load
|
Effeciency at (50Hz) 3/4 load
|
Power factor |
Rated current |
||||||||||||
kW |
|
rpm |
% |
% |
|
A |
Nm |
ILR/Irated |
TLR/Trated |
Tmax/Trated |
kgm² |
kg |
LpfA |
||
|
1000rpm 6- pole |
||||||||||||||
|
220VD/380VY 50HZ |
||||||||||||||
80M |
0.55 |
0AV3083C |
1TL0303-0DC32-1 □□□ |
935 |
77.2 |
77.5 |
0.67 |
1.62 |
5.6 |
5.0 |
2.6 |
3.2 |
0.00310 |
15 |
44 |
90S |
0.75 |
0AV3090C |
1TL0303-0EC02-1 □□□ |
940 |
78.9 |
80.3 |
0.70 |
2.05 |
7.6 |
5.0 |
2.4 |
3.2 |
0.00436 |
18.5 |
45 |
90L |
1.1 |
0AV3094C |
1TL0303-0EC42-1 □□□ |
945 |
81.0 |
81.6 |
0.69 |
3 |
11.1 |
5.5 |
2.7 |
3.5 |
0.00513 |
22 |
45 |
100L |
1.5 |
0AV3104C |
1TL0303-1AC42-1 □□□ |
950 |
82.5 |
84.1 |
0.74 |
3.75 |
15.1 |
5.5 |
2.5 |
3.5 |
0.01136 |
31 |
49 |
112M |
2.2 |
0AV3112C |
1TL0303-1BC22-1 □□□ |
945 |
84.3 |
86.1 |
0.74 |
5.4 |
22.2 |
6.0 |
2.7 |
3.4 |
0.01451 |
37 |
53 |
132S |
3 |
0AV3130C |
1TL0303-1CC02-1 □□□ |
965 |
85.6 |
86.6 |
0.75 |
7.1 |
29.7 |
6.0 |
2.7 |
4.0 |
0.02666 |
45 |
57 |
|
1000rpm 6- pole |
||||||||||||||
|
380VD/660VY 50HZ |
||||||||||||||
132M |
4 |
0AV3132C |
1TL0303-1CC23-3 □□□ |
955 |
86.8 |
88.5 |
0.75 |
9.3 |
40.0 |
6.0 |
2.7 |
3.4 |
0.0305 |
56 |
57 |
132M |
5.5 |
0AV3133C |
1TL0303-1CC33-3 □□□ |
960 |
88.0 |
89.2 |
0.76 |
12.5 |
54.7 |
6.5 |
2.7 |
4.0 |
0.0413 |
68 |
57 |
160M |
7.5 |
0AV3162C |
1TL0303-1DC23-3 □□□ |
980 |
89.1 |
90.4 |
0.78 |
16.4 |
73.1 |
6.5 |
2.7 |
3.6 |
0.126 |
78 |
61 |
160L |
11 |
0AV3164C |
1TL0303-1DC43-3 □□□ |
980 |
90.3 |
90.3 |
0.77 |
24 |
107 |
7.0 |
2.7 |
3.6 |
0.1717 |
95 |
61 |
|
750rpm 8- pole |
||||||||||||||
|
220VD/380VY 50HZ |
||||||||||||||
132S |
2.2 |
0AV3130D |
1TL0303-1CD02-1 □□□ |
725 |
81.9 |
82.6 |
0.73 |
5.6 |
29 |
5.5 |
1.8 |
3.0 |
0.0470 |
56 |
51 |
132M |
3 |
0AV3132D |
1TL0303-1CD22-1 □□□ |
720 |
83.5 |
84.5 |
0.74 |
7.4 |
39.8 |
5.5 |
1.8 |
3.0 |
0.0615 |
68 |
51 |
|
750rpm 8- pole |
||||||||||||||
|
380VD/660VY 50HZ |
||||||||||||||
160M |
4 |
0AV3162D |
1TL0303-1DD23-3 □□□ |
728 |
84.8 |
86.4 |
0.74 |
9.7 |
52.5 |
5.5 |
1.7 |
2.8 |
0.0759 |
60 |
55 |
160M |
5.5 |
0AV3163D |
1TL0303-1DD33-3 □□□ |
732 |
86.2 |
87.1 |
0.74 |
13.1 |
71.8 |
6.0 |
1.7 |
3.0 |
0.1002 |
71 |
55 |
160L |
7.5 |
0AV3164D |
1TL0303-1DD43-3 □□□ |
732 |
87.3 |
88.3 |
0.74 |
17.6 |
97.8 |
6.0 |
1.8 |
3.0 |
0.1277 |
109 |
55 |
Options
Motor order code |
Option Code |
Description |
Application Scope |
Voltages and frequency |
|||
1TL0303- □□□□ 9-0 □□□ |
M2A2)14) |
220VD/380VY 60Hz,50Hz power output |
FS80 ~ 160 |
M2B3)14) |
380VD/660VY 60Hz,50Hz power output |
FS80 ~ 160 |
|
M2C2)14) |
440VY 60Hz,50Hz power output |
FS80 ~ 160 |
|
M2D3)14) |
440VD 60Hz,50Hz power output |
FS80 ~ 160 |
|
M2E2)14) |
460VY 60Hz,50Hz power output |
FS80 ~ 160 |
|
M2F3)14) |
460VD 60Hz,50Hz power output |
FS80 ~ 160 |
|
Windings and insulation |
|||
- |
N01 |
Temperature class 155 (F), used according to 155 (F), with service factor (SF1.15) |
FS80 ~ 160 |
- |
N10 |
Temperature class 180(H) |
FS80 ~ 160 |
- |
Q044) |
Anti-condensation heater for 220 VAC (spaces heater) |
FS80 ~ 160 |
Motor connection box |
|||
- |
R10 5) 15) |
Rotation of the connection box through 90º, entry from DE |
FS80 ~ 160 |
- |
R11 6) 15) |
Rotation of the connection box through 90º, entry from NDE |
FS80 ~ 160 |
- |
R12 15) |
Rotation of the connection box through 180º |
FS80 ~ 160 |
- |
H04 |
external earthing |
FS80 ~ 160 |
- |
X07 |
cast iron connection box |
FS80 ~ 160 |
- |
X47 |
Connection boxes of the motors include 2 self-locking cable gland |
FS112 ~ 160 |
Bearings |
|||
- |
L80 |
SKF Bearing |
FS80 ~ 160 |
- |
L81 |
Other import brand bearing |
FS80 ~ 160 |
- |
L8216) |
DE shaft with threaded hole |
FS80 ~ 160 |
- |
L20 |
Located bearing at DE |
FS80 ~ 160 |
- |
L22 |
Increased cantilever forces |
FS100 ~ 160 |
1) Order No. supplement Z with option code when ordering.
2) Only applicable to the motor whose power is 3kW and below.
3) Only applicable to the motor whose power is 3kW and above.
4) When choose these options, the connection boxes will be changed to cast iron shell.
5) Not applicable to the FS80~10 flange mounted motors, and can't be used with the option H08.
6) Not applicable to the outlet on top.
7) H00、F70 can't be used with this option.
8) Second standard shaft extension on NDE is shown in the dimension drawings.
Motor order code |
Option Code |
Description |
Application Scope |
Mechanical design and degrees of protection |
|||
- |
X177)8) |
Second standard shaft extension |
FS80 ~ 160 |
- |
H009) |
Motor with protective cover |
FS80 ~ 160 |
- |
H0310) |
Drainage holes |
FS80 ~ 160 |
- |
F9011) |
Fan motor (no fan cover, NDE fully enclosed) |
FS80 ~ 160 |
- |
X5012) |
Install OMRON encoder (E6B2-CWZ6C-1024) and independent drive fan |
FS80 ~ 160 |
- |
F01 |
Install the electro-magnetic brake |
FS80 ~ 160 |
- |
W7413) |
Install the OMRON encoder (E6B2-CWZ1X-1024) and independent drive fan |
FS80 ~ 160 |
- |
F709) |
Motors with the independent drive fan |
FS80 ~ 160 |
- |
H22 |
IP56 degree of protection (non-heavy-sea) |
FS80 ~ 160 |
Rating plate and test certificates |
|||
- |
B80 |
Acceptance test certificate 3.1 in accordance with EN 10204 |
FS80 ~ 160 |
Paint finish |
|||
- |
W88 |
Design for TH, W, F1, WF1 and Sea air resistant |
FS80 ~ 160 |
Packing |
|||
- |
B90 |
Packing (FS80~132 motors adopt the carton packaging, FS160 motors adopt the wooden cases packaging) |
FS80 ~ 160 |
9) Unable to be used with the option X17.
10) Only applicable to the vertical mounting motors. For the construction type of IM B5 and IM B14, when choose this option, it is necessary to ensure the connection box is on top of the frame. For other construction types, please specially consult with SIEMENS.
11) When without the fans or the shells, the motor length will be decreased by Δl. If it is necessary to output according to the nameplate power, the motor requires external cooling. Customers are supposed to adopt the right cooling method, without or wrong cooling methods will decrease the service life for the motors. even damage the motors.
12) When the SINAMICS frequency converter is coupled with the Omron encoder (E6B2-CWZ6C), the frequency converter requires some special configuration. For more information, please consult the SIEMENS hotline.
13) SINAMICS frequency converter can be directly coupled with the Omron encoder (E6B2-CWZ1X).
14) According to the requirements of the GB, the energy efficiency
requirement is not evaluated under the frequency of 60Hz.
15) When connection box on the right or left side of motor, the cable entry from below as default.
16) Threaded hole size is shown in the DB size of the section of dimension drawings.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.